Seiko Instruments Inc.
Seach HOMEJAPANESEChinese
Whats New? Events Products Technology Distribution Channel Corporate Information Contact Us
Products
Product Lineup
Thermal Analysis (DSC, TG, DTA, TMA, DMA)
Thermal Analysis / Rheology System(DSC, TG/DTA, TMA, DMA)Product Lineup
Special Contents: X-DSC7000
Thermal Analysis / Rheology System(DSC, TG/DTA, TMA, DMA)Descriptions
Thermal Analysis / Rheology System(DSC, TGA, TMA, DMA)Applications
Thermal Analysis / Rheology System(DSC, TGA, TMA, DMA)Standards
Thermal Analysis / Rheology System(DSC, TGA, TMA, DMA)References
Scanning Probe Microscope (SPM)
Focused Ion Beam (FIB) / Scanning Ion Microscope (SIM)
ICP-OES(ICP-AES). ICP-MS
Photomask Repair
XRF Analysis
XRF Coating Thickness Measurements
Transmission Electron Microscope/Scanning Electron Microscope / Scanning Electron Microscope (TEM/SEM)
Mask Data Preparation Software (MDP)
X-ray Detector
Pre-Clinical Imaging System (CT-PET-SPECT)
Price Inquiry
Price Inquiry Form
Supplies Price Chart
Technology
Distribution Channel
Testing Laboratories

 Definitions of Thermogravimetry (TG)

A technique in which the mass of the sample is monitored against time or temperature while the temperature of the sample, in a specified atmosphere, is programmed.
This is definition of TG by ICTAC.

 Definitions of simultaneous Thermogravimetry and Differential Thermal Analysis (TG/DTA, TGA/DTA)

A method in which thermogravimetry and differential thermal analysis are combined and measured simultaneously by a single apparatus.
This is definition of TG-DTA by JIS (Japanese Industrial Standard)


As defined above, TG is a technique that measures mass change in a sample, and it is used to detect evaporation, decomposition, oxidation and other effects of temperature change that cause mass changes.

[Description of TG/DTA]

Block diagram of horizontal differential TG/DTA
Figure 1. Block diagram of horizontal differential TG/DTA

Figure 1 shows the The balance beams for the sample and the reference are located in the furnace. The masses of the sample and the reference are measured by the sensitivity-calibrated drive coils separately. The mass difference is sent as TG signal. By the differential mass measurement, the effects of the beam expansion, the convection flow, and buoyant force are cancelled. Thus the highly sensitive thermogravimetry measurement is achieved. The mass measurement of the sample and the reference by the independent drive coils enables the easy adjustment of the TG baseline drift electrically.

Also, thermocouple is located in each holder which enables the simultaneous DTA signal output.

TG can be utilized for the analysis of the thermal decomposition, the oxidization, the dehydration, the heat resistance, and kinetics analysis. By combining with the other measurement technique, variety of information can be achieved from one sample. In particular, TG/DTA simultaneous measurement instrument is most common.

Description of other analysis method:
•Thermal Analysis
•Differential Scanning Calorimetry (DSC)
•Differential Thermal Analysis (DTA)
•Thermomechanical Analysis (TMA)
•Dynamic Mechanical Analysis (DMA)


Thermal Analysis Top
SII HOME
• Terms of Use   • Privacy Policy   • Site Map  
Copyright © 2012 SII NanoTechnology Inc. All Rights Reserved.